List of Parameters
p1930
Voltage setpoint for calibration / Volt setp. calibr.
Access level: 4
Quick comm. NO
Can be changed: U, T
Min
0 [V]
Description:
Specifies reference voltage for generation of a test voltage vector (e.g. used for shunt calibration). [V]
p1931
Phase / Phase
Access level: 4
Quick comm. NO
Can be changed: U, T
Min
1
Description:
Defines phase of voltage vector
1: u-axis
2: v-axis
3: w-axis
4: -u-axis
5: -v-axis
6: -w-axis
7: uv-axis (30°)
8: wu-axis (150°)
9: vw-axis (270°)
10: -uv-axis (210°)
11: -wu-axis (330°)
12: -vw-axis (90°)
1-194
P-Group: Motor identification
Active: YES
Max
1000 [V]
P-Group: Motor identification
Active: YES
Max
12
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
Data type: Floating Point
Data set: -
Factory setting
0 [V]
Data type: Unsigned16
Data set: -
Factory setting
1