List of Parameters
p0625[0...2]
Ambient motor temperature / Ambient mot. temp.
Access level: 3
Quick comm. YES
Can be changed: C, U, T
Min
-40.0 [°C]
Description:
Ambient temperature of motor at time of motor data identification.
It is only allowed to change the value when the motor is cold.
A motor identification has to be made after changing the value.
p0626[0...2]
Overtemperature stator iron / Overtemp.stat.iron
Access level: 4
Quick comm. NO
Can be changed: U, T
Min
20.0 [°C]
Description:
Overtemperature of stator iron.
Note:
Temperature rises are valid for sinusoidal operations (line supply temperature rises).
Temperature rises due to converter operation (modulation losses) and output filter are also considered.
p0627[0...2]
Overtemperature stator winding / Overtemp.stat.wind
Access level: 4
Quick comm. NO
Can be changed: U, T
Min
20.0 [°C]
Description:
Overtemperature of the stator winding.
It is only allowed to change the value when the motor is cold.
A motor identification has to be made after changing the value.
Note:
Temperature rises are valid for sinusoidal operations (line supply temperature rises).
Temperature rises due to converter operation (modulation losses) and output filter are also considered.
p0628[0...2]
Overtemperature rotor winding / Overtemp.rot. wind
Access level: 4
Quick comm. NO
Can be changed: U, T
Min
20.0 [°C]
Overtemperature of the rotor winding.
Description:
Note:
Temperature rises are valid for sinusoidal operations (line supply temperature rises).
Temperature rises due to converter operation (modulation losses) and output filter are also considered.
r0630[0...2]
CO: Motor model ambient temperature / Mot. model amb. te
Access level: 4
Unit: [°C]
Description:
Displays ambient temperature of motor mass model.
1-62
P-Group: Motor
Active: YES
Max
80.0 [°C]
P-Group: Motor
Active: YES
Max
200.0 [°C]
P-Group: Motor
Active: YES
Max
200.0 [°C]
P-Group: Motor
Active: YES
Max
200.0 [°C]
P-Group: Motor
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
Data type: Floating Point
Data set: DDS
Factory setting
20.0 [°C]
Data type: Floating Point
Data set: DDS
Factory setting
50.0 [°C]
Data type: Floating Point
Data set: DDS
Factory setting
80.0 [°C]
Data type: Floating Point
Data set: DDS
Factory setting
100.0 [°C]
Data type: Floating Point
Data set: DDS