Siemens Sinamics G120 Series Parameter Manual page 306

Hide thumbs Also See for Sinamics G120 Series:
Table of Contents

Advertisement

Parameters
Connector/Binector (BICO)-Parameters
1.4
Connector/Binector (BICO)-Parameters
1.4.1
Binector Input Parameters
p0731[0...2]
p0732[0...2]
p0733[0...2]
p0800[0...2]
p0801[0...2]
p0806
p0810
p0811
p0820
p0821
p0840[0...2]
p0842[0...2]
p0844[0...2]
p0845[0...2]
p0848[0...2]
p0849[0...2]
p0852[0...2]
p1020[0...2]
p1021[0...2]
p1022[0...2]
p1023[0...2]
p1035[0...2]
p1036[0...2]
p1041[0...2]
p1043[0...2]
p1055[0...2]
p1056[0...2]
p1074[0...2]
p1110[0...2]
p1113[0...2]
p1124[0...2]
p1140[0...2]
p1141[0...2]
p1142[0...2]
p1230[0...2]
p1477[0...2]
p1492[0...2]
p1501[0...2]
p2103[0...2]
p2104[0...2]
p2106[0...2]
p2200[0...2]
p2220[0...2]
p2221[0...2]
p2222[0...2]
p2223[0...2]
1-306
BI: Function of digital output 0 / Fct. of DO0
BI: Function of digital output 1 / Fct. of DO1
BI: Function of digital output 2 / Fct. of DO2
BI: Download parameter set 0 / Dwnl.par.set 0
BI: Download parameter set 1 / Dwnl.par.set 1
BI: Inhibit panel access / Inhibit panel acce
BI: CDS bit 0 (Hand/Auto) / CDS bit 0
BI: CDS bit 1 / CDS bit 1
BI: DDS bit 0 / DDS bit 0
BI: DDS bit 1 / DDS bit 1
BI: ON/OFF1 / ON/OFF1
BI: ON reverse/OFF1 / BI:ON reverse/OFF1
BI: 1. OFF2 / 1. OFF2
BI: 2. OFF2 / 2. OFF2
BI: 1. OFF3 / 1. OFF3
BI: 2. OFF3 / 2. OFF3
BI: Pulse enable / Pulse enable
BI: Fixed freq. selection Bit 0 / FF sel. Bit 0
BI: Fixed freq. selection Bit 1 / FF sel. Bit 1
BI: Fixed freq. selection Bit 2 / FF sel. Bit 2
BI: Fixed freq. selection Bit 3 / FF sel. Bit 3
BI: Enable MOP (UP-command) / Enable MOP(UP)
BI: Enable MOP (DOWN-command) / Enable MOP(DWN)
BI: MOP select setpoint automatically/manually / Setp. auto/manu
BI: MOP accept rampgenerator setpoint / MOP acc RFG setpo
BI: Enable JOG right / Enable JOG ->
BI: Enable JOG left / Enable JOG <-
BI: Disable additional setpoint / Disab.add.setp
BI: Inhibit neg. freq. setpoint / Inh. neg. setp
BI: Reverse / Reverse
BI: Enable JOG ramp times / Enable JOG ramp
BI: RFG enable / RFG enable
BI: RFG start / RFG start
BI: RFG enable setpoint / RFG enable setp
BI: Enable DC braking / Enable DC brk.
BI: Set integrator of n-ctrl. / Set integrator
BI: Enable droop / Enable droop
BI: Change to torque control / BI:-> torque ctrl.
BI: 1. Faults acknowledgement / 1. Faults ackn
BI: 2. Faults acknowledgement / 2. Faults ackn
BI: External fault / External fault
BI: Enable PID controller / Enab. PID ctrl
BI: Fixed PID setp. select Bit 0 / BI:PID setp->Bit 0
BI: Fixed PID setp. select Bit 1 / BI:PID setp->Bit 1
BI: Fixed PID setp. select Bit 2 / BI:PID setp->Bit 2
BI: Fixed PID setp. select Bit 3 / BI:PID setp->Bit 3
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu240s dpCu240s dp-fCu240sCu240s pn

Table of Contents