Parameters
List of Parameters
p0095[0...9]
CI: Display PZD signals / PZD signals
Access level: 3
Quick comm. NO
Can be changed: T
Min
-
Description:
Selects source of display for PZD signals.
Index:
[0] = 1st PZD signal
[1] = 2nd PZD signal
[2] = 3rd PZD signal
[3] = 4th PZD signal
[4] = 5th PZD signal
[5] = 6th PZD signal
[6] = 7th PZD signal
[7] = 8th PZD signal
[8] = 9th PZD signal
[9] = 10th PZD signal
r0096[0...9]
PZD signals / PZD signals
Access level: 3
Unit: [%]
Description:
Displays PZD signals in [%].
Index:
[0] = 1st PZD signal
[1] = 2nd PZD signal
[2] = 3rd PZD signal
[3] = 4th PZD signal
[4] = 5th PZD signal
[5] = 6th PZD signal
[6] = 7th PZD signal
[7] = 8th PZD signal
[8] = 9th PZD signal
[9] = 10th PZD signal
Note:
r0096 = 100 % corresponds to 4000 hex.
p0100
Europe / North America / Europe / Nth Amer.
Access level: 1
Quick comm. YES
Can be changed: C
Min
0
Description:
Determines whether power settings are expressed in [kW] or [hp] (e.g. Rated motor power P0307).
The default settings for the rated motor frequency P0310 and maximum frequency P1082 are also set automatically
here, in addition to reference frequency P2000.
Values:
0:
1:
2:
Dependency:
Where:
•
Stop drive first (i.e. disable all pulses) before you change this parameter.
•
Parameter P0100 can only be changed with P0010 = 1 (Commissioning mode) via the respective interface (e.g.
USS on RS232).
•
Changing P0100 resets all rated motor parameters as well as other parameters that depend on the rated motor
parameters (see P0340 - calculation of motor parameters).
1-32
Europe [kW],
motor base frequency is 50 Hz
North America [hp], motor base frequency is 60 Hz
North America [kW], motor base frequency is 60 Hz
P-Group: Closed-loop control
Active: NO
Max
-
P-Group: Closed-loop control
P-Group: -
Active: NO
Max
2
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
Data type: Unsigned32
Data set: -
Factory setting
0
Data type: Floating Point
Data set: -
Data type: Unsigned16
Data set: -
Factory setting
0