Parameters
List of Parameters
r0968
Status word 1 / Status word 1
Access level: 3
Unit: -
Description:
Displays active status word of inverter (in binary) and can be used to diagnose which commands are active.
Bit field:
Bit
Signal name
00
Drive ready
01
Drive ready to run
02
Drive running
03
Drive fault active
04
OFF2 active
05
OFF3 active
06
ON inhibit active
07
Drive warning active
08
Deviation setpoint / act. value
09
PZD control
10
f_act >= P1082 (f_max)
11
Warning: Motor current/torque limit
12
Brake open
13
Motor overload
14
Motor runs right
15
Inverter overload
p0969
Resetable system run time counter / Rst counter
Access level: 3
Quick comm. NO
Can be changed: T
Min
0
Description:
Resetable system run time counter.
1-106
P-Group: Communications
1 signal
Yes
Yes
Yes
Yes
No
No
Yes
Yes
No
Yes
Yes
No
Yes
No
Yes
No
P-Group: Messages
Active: YES
Max
4294967295
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
Data type: Unsigned16
Data set: -
0 signal
FP
No
-
No
-
No
-
No
-
Yes
-
Yes
-
No
-
No
-
Yes
-
No
-
No
-
Yes
-
No
-
Yes
-
No
-
Yes
-
Data type: Unsigned32
Data set: -
Factory setting
0

Hide quick links: