Parameters
List of Parameters
p1211
Number of restart attempts / Restart attempts
Access level: 3
Quick comm. NO
Can be changed: C, U, T
Min
0
Description:
Specifies number of times inverter will attempt to restart if automatic restart P1210 is activated.
p1215
Holding brake enable / MHB enable
CU240E
Access level: 2
Quick comm. NO
Can be changed: C, T
Min
0
Description:
Enables/disables holding brake function.
The mechanical motor holding brake (MHB) is controlled via the signal of status word 1 r0052 Bit12 "Brake open".
This signal can be issued via:
status word of the serial interface (e.g. USS)
digitial outputs (e.g. DO0: ==> P0731 = 52.C (r0052 Bit12))
Values:
0:
1:
It is not permissible to use the motor holding brake as working brake, as it is generally only designed for a limited
Caution:
number of emergeny braking operations.
Note:
In V/f control (P1300 < 20) a typical value of min. frequency P1080 for motor holding brake is the slip frequency of
the motor r0330.
f
Slip
In a vector control mode (P1300 = 20) the following should be valid:
The value of the min. Frequency P1080 should be zero.
The delay speed loss reaction should be > brake holding times (i.e. P0494 > P1216 and P0494 > P1217 )
The delay time for motor pulled out should be > brake holding times (i.e. P2178 > P1216 and P2178 > P1217 )
Otherwise there may be encoder loss trips (F0090) when the brake is applied and pulses are enabled.
p1215
Holding brake enable / MHB enable
CU240S
Access level: 2
CU240S DP
Quick comm. NO
CU240S DP-F
Can be changed: C, T
CU240S PN
Min
0
Description:
Enables/disables holding brake function.
The mechanical motor holding brake (MHB) is controlled via the signal of status word 1 r0052 Bit12 "Brake open".
This signal can be issued via:
status word of the serial interface (e.g. USS)
digitial outputs (e.g. DO0: ==> P0731 = 52.C (r0052 Bit12))
Values:
0:
1:
1-142
Motor holding brake disabled
Motor holding brake enabled
r0330
n
sy
n
=
=
[Hz]
P0310
100
n
Motor holding brake disabled
Motor holding brake enabled
P-Group: -
Active: NO
Max
10
P-Group: -
Active: NO
Max
1
n
n
f
n
sy
n
P-Group: -
Active: NO
Max
1
SINAMICS G120 Control Units CU240S, Edition 05/2007
Data type: Unsigned16
Data set: -
Factory setting
3
Data type: Unsigned16
Data set: -
Factory setting
0
Data type: Unsigned16
Data set: -
Factory setting
0
© Siemens AG 2007 All Rights Reserved