r0947[0...63]
CO: Last fault code / Last fault code
CU240S DP-F
Access level: 2
Unit: -
Description:
Displays fault history.
Index:
[0] = Recent fault trip --, fault 1
[1] = Recent fault trip --, fault 2
[2] = Recent fault trip --, fault 3
[3] = Recent fault trip --, fault 4
[4] = Recent fault trip --, fault 5
[5] = Recent fault trip --, fault 6
[6] = Recent fault trip --, fault 7
[7] = Recent fault trip --, fault 8
[8] = Recent fault trip -1, fault 1
Dependency:
Index 1 used only if second fault occurs before first fault is acknowledged.
Notice:
It is possible that this parameter is empty but a fault is still indicated by the drive. The reason for this is most likely
due to a SAFE condition still existing in the system. In this situation the alarm is cleared from this parameter and it
makes no sense to go back to a READY state. First remove the reason for the SAFE condition and then the drive
will be able to change to a READY state. (SAFE condition example is "safety function is activated").
Note:
See Chapter "Faults and Warnings".
r0948[0...63]
Fault time / Fault time
CU240E
Access level: 3
CU240S
Unit: -
Description:
Time stamp to indicate when a fault has occurred.
P2114 (run-time counter) or P2115 (real time clock) are the possible sources of the time stamp.
In case of PROFIdrive Profile 3.1 or higher configuration, P0969 (system run time counter) is used.
Index:
[0] = Recent fault trip --, fault time 1
[1] = Recent fault trip --, fault time 2
[2] = Recent fault trip --, fault time 3
[3] = Recent fault trip --, fault time 4
[4] = Recent fault trip --, fault time 5
[5] = Recent fault trip --, fault time 6
[6] = Recent fault trip --, fault time 7
[7] = Recent fault trip --, fault time 8
[8] = Recent fault trip -1, fault time 1
Note:
P2115 can be updated via Starter, DriveMonitor, etc.
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
P-Group: Messages
P-Group: Messages
Parameters
List of Parameters
Data type: Unsigned16
Data set: -
Data type: Unsigned32
Data set: -