Siemens Sinamics G120 Series Parameter Manual page 259

Hide thumbs Also See for Sinamics G120 Series:
Table of Contents

Advertisement

p2816[0...1]
BI: OR 1 / OR 1
Access level: 3
Quick comm. NO
Can be changed: U, T
Min
-
Description:
P2816[0], P2816[1] define inputs of OR 1 element, output is P2817.
Index:
[0] = Binector input 0 (BI 0)
[1] = Binector input 1 (BI 1)
Dependency:
P2801[3] is active level for the OR element.
r2817.0
BO: OR 1 / OR 1
Access level: 3
Unit: -
Description:
Output of OR 1 element.
Displays or logic of bits defined in P2816[0], P2816[1].
Bit field:
Bit
Signal name
00
Output of BO
Dependency:
P2801[3] is active level for the OR element.
p2818[0...1]
BI: OR 2 / OR 2
Access level: 3
Quick comm. NO
Can be changed: U, T
Min
-
Description:
P2818[0], P2818[1] define inputs of OR 2 element, output is P2819.
Index:
[0] = Binector input 0 (BI 0)
[1] = Binector input 1 (BI 1)
Dependency:
P2801[4] is active level for the OR element.
r2819.0
BO: OR 2 / OR 2
Access level: 3
Unit: -
Description:
Output of OR 2 element.
Displays or logic of bits defined in P2818[0], P2818[1].
Bit field:
Bit
Signal name
00
Output of BO
Dependency:
P2801[4] is active level for the OR element.
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
p2800 p2801[3]
p2816
A
1
C
Index0
B
Index1
P-Group: Technology
Active: NO
Max
-
A
B
0
0
0
1
r2817
1
0
1
1
P-Group: Technology
1 signal
Yes
P-Group: Technology
Active: NO
Max
-
P-Group: Technology
1 signal
Yes
Parameters
List of Parameters
Data type: Unsigned32
Data set: -
Factory setting
0
C
0
1
1
1
Data type: Unsigned16
Data set: -
0 signal
No
Data type: Unsigned32
Data set: -
Factory setting
0
Data type: Unsigned16
Data set: -
0 signal
No
FP
-
FP
-