p0014[0...2]
Store mode / Store mode
Access level: 3
Quick comm. NO
Can be changed: U, T
Min
0
Description:
Sets the store mode for parameters.
The store mode can be configured for all interfaces listed under "Index".
Values:
0:
1:
Index:
[0] = USS on RS485
[1] = USS on RS232
[2] = Fieldbus
Note:
An independent store request may be part of the serial communications (e.g. PKE bits 15-12 of USS protocol), set
by a PLC or PC tools like STARTER. See the table below for an influence on the settings of P0014.
Value of p0014[x]
1. With the BOP the parameter will always be stored in the EEPROM.
2. P0014 itself will always be stored in the EEPROM.
3. P0014 will not be changed by performing a factory reset (P0010 = 30 and P0970 = 1).
4. P0014 can be transferred during a download (P0010 = 29).
When transferring parameter p0014, the inverter uses its processor to carry-out internal calculations. Communica-
tions - both via USS as well as via the Fieldbus - are interrupted for the time that it takes to make these calculations.
This can result in the following error messages at the connected SIMATIC S7 control (communications via fieldbus):
Parameter fault 30
Drive fault 70
Drive fault 75
When using STARTER (USS) to commission the drive system, data cannot be entered while these calculations are
being made.
The faults can be acknowledged as soon as the calculations have been completed in the frequency inverter. These
calculations can take up to one minute to complete.
r0018
Firmware version / Firmware version
Access level: 1
Unit: -
Description:
Displays version number of installed firmware.
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
Volatile
(RAM)
Nonvolatile (EEPROM)
Store request via USS/PROFIBUS
RAM
EEPROM
RAM
EEPROM
P-Group: -
Active: NO
Max
1
EEPROM
EEPROM
RAM
RAM
P-Group: Converter
Parameters
List of Parameters
Data type: Unsigned16
Data set: -
Factory setting
0
Result
EEPROM
EEPROM
RAM
EEPROM
Data type: Floating Point