Siemens Sinamics G120 Series Parameter Manual page 208

Hide thumbs Also See for Sinamics G120 Series:
Table of Contents

Advertisement

Parameters
List of Parameters
r2032.0...15
BO: CtrlWrd1 from USS on RS232 / CtrlWd1 <- USS
Access level: 3
Unit: -
Description:
Displays control word 1 from USS on RS232 (word 1 within USS).
Bit field:
Bit
Signal name
00
ON/OFF1
01
OFF2: Electrical stop
02
OFF3: Fast stop
03
Pulse enable
04
RFG enable
05
RFG start
06
Setpoint enable
07
Fault acknowledge
08
JOG right
09
JOG left
10
Control from PLC
11
Reverse (setpoint inversion)
13
Motor potentiometer MOP up
14
Motor potentiometer MOP down
15
CDS Bit 0 (Hand/Auto)
r2033.0...15
BO: CtrlWrd2 from USS on RS232 / CtrlWd2 <- USS
PM240
Access level: 3
Unit: -
Description:
Displays control word 2 from USS on RS232 (i.e. word 4 within USS).
Bit field:
Bit
Signal name
00
Fixed frequency Bit 0
01
Fixed frequency Bit 1
02
Fixed frequency Bit 2
03
Fixed frequency Bit 3
04
Drive Dataset (DDS) Bit 0
05
Drive Dataset (DDS) Bit 1
08
Enable PID
09
Enable DC brake
11
Enable Droop
12
Torque control
13
External fault 1
15
Command Dataset (CDS) Bit 1
Dependency:
P0700 = 4 (USS on RS232) and P0719 = 0 (Cmd / Setpoint = BICO parameter).
r2033.0...15
BO: CtrlWrd2 from USS on RS232 / CtrlWd2 <- USS
PM250
Access level: 3
PM260
Unit: -
Description:
Displays control word 2 from USS on RS232 (i.e. word 4 within USS).
Bit field:
Bit
Signal name
00
Fixed frequency Bit 0
01
Fixed frequency Bit 1
02
Fixed frequency Bit 2
03
Fixed frequency Bit 3
04
Drive Dataset (DDS) Bit 0
05
Drive Dataset (DDS) Bit 1
08
Enable PID
11
Enable Droop
12
Torque control
13
External fault 1
15
Command Dataset (CDS) Bit 1
Dependency:
P0700 = 4 (USS on RS232) and P0719 = 0 (Cmd / Setpoint = BICO parameter).
1-208
P-Group: Communications
1 signal
Yes
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
P-Group: Communications
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
P-Group: Communications
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
Data type: Unsigned16
Data set: -
0 signal
FP
No
-
Yes
-
Yes
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
Data type: Unsigned16
Data set: -
0 signal
FP
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
Yes
-
No
-
Data type: Unsigned16
Data set: -
0 signal
FP
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
Yes
-
No
-