Siemens Sinamics G120 Series Parameter Manual page 222

Hide thumbs Also See for Sinamics G120 Series:
Table of Contents

Advertisement

Parameters
List of Parameters
p2157[0...2]
Threshold frequency f_2 / Threshold freq f_2
Access level: 2
Quick comm. NO
Can be changed: U, T
Min
0.00 [Hz]
Description:
Threshold_2 for comparing speed or frequency to thresholds as illustrated in the diagram below.
| f_act | <= f_2
| f_act | > f_2
f_act
p2158[0...2]
Delay time of threshold freq f_2 / Delay time of f_2
Access level: 2
Quick comm. NO
Can be changed: U, T
Min
0 [ms]
Description:
When comparing speed or frequency to threshold f_2 (P2157).
This is the time delay before status bits are cleared.
Note:
See diagram in P2157 (threshold frequency f_2)
1-222
r2169
Tconst. speed filt
0 ... 1000 [ms]
P2153.D (5)
P-Group: Messages
Active: YES
Max
650.00 [Hz]
Threshold freq f_2
0.00 ... 650.00 [Hz]
P2157.D (30.00)
Threshold freq f_2
0.00 ... 650.00 [Hz]
P2157.D (30.00)
Hyst. freq. f_hys
0.00 ... 10.00 [Hz]
P2150.D (3.00)
1
0
Hyst. freq. f_hys
0.00 ... 10.00 [Hz]
P2150.D (3.00)
P-Group: Messages
Active: YES
Max
10000 [ms]
SINAMICS G120 Control Units CU240S, Edition 05/2007
Data type: Floating Point
Data set: DDS
Factory setting
30.00 [Hz]
Delay time of f_2
0 ... 10000 [ms]
P2158.D (10)
| f_act | <= f_2
1
0
T
0
r2198 Bit00
| f_act | > f_2
0
T
r2198 Bit01
Delay time of f_2
0 ... 10000 [ms]
P2158.D (10)
Data type: Unsigned16
Data set: DDS
Factory setting
10 [ms]
© Siemens AG 2007 All Rights Reserved

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu240s dpCu240s dp-fCu240sCu240s pn