p1325[0...2]
Programmable V/f volt. coord. 3 / V/f volt. coord. 3
Access level: 3
Quick comm. NO
Can be changed: U, T
Min
0.0 [V]
Description:
See P1320 (programmable V/f freq. coord. 1).
p1330[0...2]
CI: Voltage setpoint / Voltage setp.
Access level: 3
Quick comm. NO
Can be changed: T
Min
-
Description:
BICO parameter for selecting source of voltage setpoint for independent V/f control (P1300 = 19).
p1333[0...2]
Start frequency for FCC / Start freq for FCC
Access level: 3
Quick comm. NO
Can be changed: U, T
Min
0.0 [%]
Description:
Defines start frequency at which FCC (flux current control) is enabled as [%] of rated motor frequency (P0310).
Notice:
If this value is too low, the system may become unstable.
p1334[0...2]
Slip compensation activation range / Slip c. act. range
Access level: 3
Quick comm. NO
Can be changed: U, T
Min
1.0 [%]
To set the frequency activation range for slip compensation. The percentage value of P1334 refers to the motor
Description:
rated frequency P0310.
The upper threshold will always stay 4 % above P1334.
Range of slip compensation :
P1335
Dependency:
Slip compensation (P1335) active.
Note:
See parameter P1335.
The starting frequency of the slip compensation is P1334 * P0310.
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
%
P1334
P1334+4 %
100 %
P-Group: Closed-loop control
Active: YES
Max
3000.0 [V]
P-Group: Closed-loop control
Active: NO
Max
-
P-Group: Closed-loop control
Active: YES
Max
100.0 [%]
P-Group: Closed-loop control
Active: YES
Max
20.0 [%]
f
out
f
N
f
out
f
N
P1334 P1334+4 %
Parameters
List of Parameters
Data type: Floating Point
Data set: DDS
Factory setting
0.0 [V]
Data type: Unsigned32
Data set: CDS
Factory setting
0
Data type: Floating Point
Data set: DDS
Factory setting
10.0 [%]
Data type: Floating Point
Data set: DDS
Factory setting
6.0 [%]
with
slip compensation
without
slip compensation
f
set
f
N
1-161

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu240s dpCu240s dp-fCu240sCu240s pn

Table of Contents