Cleaning Air Filter Housing - Skoda Rapid NH 2013 Maintenance, Workshop Manual

Hide thumbs Also See for Rapid NH 2013:
Table of Contents

Advertisement

– Locate the air filter lower part -3- on the air filter upper part
-1-.
– Bolt together the air filter lower part air and air filter upper part
with screws -1-, and tighten to the required tightening torque.
Note
Self-cutting screws are used as standard equipment for fas‐
tening the air filter upper part on the air filter lower part.
Loosening or tightening these screws with a power driving tool
can cause damage to the intake manifold or the thread in the
air filter lower part.
For this reason, use of a power driving tool is only permissible
if the maximum power driving tool rotational speed is 200 rpm
and a max. tightening torque of 1.6 Nm is set.
When installing the air filter housing, take care to route the
water drain pipe correctly.
– The remaining steps for installing the air filter housing are as
above in reverse order.
Tightening torque
Fixing screws
3.15.7

Cleaning air filter housing

Note
Cleaning is charged separately.
– Check the water drain hose in the air filter lower part for soiling
and blockage; clean if required.
– Remove salt residues, dirt and leaves from the air filter hous‐
ing.
Note
When blowing out the air filter housing using compressed air,
cover critical air-carrying components with clean cloths.
Rapid NH 2013 ➤ , Rapid NH 2014 ➤
Maintenance - Edition 06.2018
Nm
1.5
101

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rapid nh 2014

Table of Contents