Skoda Rapid NH 2013 Maintenance, Workshop Manual page 162

Hide thumbs Also See for Rapid NH 2013:
Table of Contents

Advertisement

Rapid NH 2013 ➤ , Rapid NH 2014 ➤
Maintenance - Edition 06.2018
and legislation of the relevant country ⇒ Owner's Manual for the
headlight beam setting device .
Test and setting conditions
Tyre pressure o.k.
Lenses must neither be damaged nor soiled.
Reflectors and bulbs o.k.
The headlight beam setting is carried out by turning the control
for headlamp range control to the basic setting "–".
Vehicle load must be achieved: with one person or 75 kg on
the driver's seat in an otherwise unladen vehicle (unladen
weight).
The unladen weight is the weight of the vehicle with full fuel tank
(at least 90%) including the weight of all the operational equip‐
ment elements (e.g. spare wheel, tool kit, jack etc.).
If the fuel tank is not filled up to at least 90%, the load must be set
as follows:
– Determine the fuel volume in the fuel tank on the fuel gauge
display.
– Load vehicle with corresponding weight via the fuel tank ac‐
cording to the following table:
Fuel gauge
Weight (kg)
Reserve
27
1/4
24
1/2
15
3/4
6
Fuel tank full 0
Note
Use as weight e.g. plastic tanks filled with water or petrol can‐
isters. 1 litre of water = 1 kg.
When fitting the weight onto the rear seat pay special attention
so that the seat upholsteries are not dirty or damaged.
The vehicle must have rolled a few metres or have been de‐
pressed a few times at the front and rear to allow the springs to
settle.
The vehicle and the headlight beam setting device must be on
a level surface.
Align the vehicle and the headlight beam setting device in ac‐
cordance with the instructions of the device manufacturer.
For vehicles with headlight beam control in the dash panel or
in infotainment, check the system is functioning. Then set the
range to basic position with the knurled wheel or via the info‐
tainment.
For vehicles equipped with Xenon headlights and automatic
headlight beam control perform first of all the basic setting
⇒ Vehicle diagnostic tester.
Set the inclination value.
Inclination value:
Basic setting for the inclination value adjustment: -1%
158
6. Electrical System

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rapid nh 2014

Table of Contents