Skoda Rapid NH 2013 Maintenance, Workshop Manual page 70

Hide thumbs Also See for Rapid NH 2013:
Table of Contents

Advertisement

Rapid NH 2013 ➤ , Rapid NH 2014 ➤
Maintenance - Edition 06.2018
DANGER!
Instructions for engines with exhaust gas turbocharger:
After the first engine start, change the engine oil and the oil
filter and comply with the following:
♦ The engine must only run in idle when the oil pressure
warning light is lit in the dash panel insert.
♦ Do not accelerate!
♦ Once the oil pressure warning light goes out in the dash
panel insert, the full oil pressure is reached and acceler‐
ating is possible.
In case of sudden gas shocks, the turbocharger can be dam‐
aged or totally destroyed!
The turbocharger runs at very high speeds and can therefore
be severely damaged or totally destroyed within a few seconds
due to insufficient bearing lubrication!
Switch off the engine immediately in the event of an oil leakage,
vibrations or unusual noise from the turbocharger.
– Check the engine oil level again and top up with oil if neces‐
sary.
– Wait at least 3 minutes after topping up the oil again before
inspecting the oil level again.
– Install the noise insulation.
Note
The oil level must not be above the -Max- marking to avoid dam‐
age to the catalytic converter. See Inspecting engine oil level
⇒ "3.9 Inspecting engine oil level", page 62
3.10.2
Vehicles with a petrol engine; draining
and topping up with engine oil, starting
from MY 2016
– Take off cap.
– Remove the noise insulation.
– Loosen oil filter and unscrew
⇒ "3.4.2 Replacing engine oil filter for petrol engines starting
from MY 2016", page 57
Drain engine oil at 1st. oil change
Draining engine oil after 2nd and any further oil change
⇒ page 67
Drain engine oil at 1st. oil change
– Unscrew and dispose of oil drain plug with captive gasket ring
-1-.
66
.
.
⇒ page 66