4. Faults and diagnostics
4.3.4 Diagnostic code and additional information with reset, switching on
and configuration
Diagnostic number
No.
Description
1
Successful: All the fault messages were deleted.
2
Not successful: Not all messages could be deleted.
3
New start of the axis performed.
Additional information
Info
Description
Byte 1
Number of resets so far
Byte 2
reserved
Byte 3 + 4 In case value > 0: Reset duration in milliseconds after restart of the axis
Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH
The diagnostic memory contains other diagnostic events
along with faults and warnings. Here the contents of what the
diagnostic number and additional information means is de
scribed.
Diagnostic event 3: Reset
A reset command was executed with FCT or with the PLC.