A.2.2 Step−for−step instructions for basic parametrising
Step 1:
Switch on con
troller. Status C00
is now active.
Step 2:
Select commis
sioning mode
B7
CCON
OPM2
Set
1
point
SCON
OPM2
Set
1
point
A−12
1. Check status (read PNU 1192:02 −> setpoint = 0).
2. Recommendation: Write device names (PNU 121).
Basically the default value CMAX1" can be used, but an
individual name is recommendable in case you also in
tend to access the controller with FCT.
3. Check version number of the firmware (read PNU 101).
Prior to parametrising you should ensure that the CMAX
is really compatible with the following project data.
4. Activate Commissioning" mode in the CCON, wait for
acknowledgement in the SCON.
STOP and ENABLE must not be set.
B6
B5
B4
OPM1
LOCK
0
x
0
OPM1
FCT_MMI 24VL
0
x
x
If the parameters are to transmitted via the cyclical I/O data
of the PLC, Parametrising" mode must be selected.
OPM2
OPM1
1
0
1
1
B3
B2
RESET
BRAKE
x
x
FAULT
WARN
0
0
Operating
Transmit parameters via
mode
Commissioning CI/DIAG or module para
meters, e.g. DPV1
Parametrisa
Usage of cyclical I/O data
tion
bytes 2..8
Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH
B1
B0
STOP
ENABLE
0
0
OPEN
ENABLED
0
0