5. Parameter
5.1

General parameter structure of the CMAX

Group
Device data
Axis data
Diagnostic data
Process data
Record list
Project data
Setpoint value for Direct
operating
Default values
Drive configuration
Controller data
Commissioning data
Tab. 5/1: Parameter structure
Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH
The CMAX contains a parameter set with the following structure.
Indices
100 ... 199
200 ... 299
300 ... 399
400 ... 499
500 ... 529
530 ... 599
600 ... 699
1100 ... 1149 All axis−specific parameters for pneumatic
1150 ... 1189 Amplification factors, identification, adapta
1190 ... 1199 Actual configuration, system of measure
Description
Device identification and device−specific
settings, version numbers, identifier
words, etc.
Memory for diagnostic events: fault
numbers, fault time, current messages.
Current setpoint values and actual values,
status data
For record select operating mode.
A record contains all the setpoint value
parameters required for a positioning pro
cedure.
Basic project settings: Project zero point,
setpoint value limits for position, force,
speed, ...
Data for jogging and direct setpoint specifi
cation for position, force, ...
Global default values
drives: Cylinder lengths and diameter, valve
type, ...
tion.
ment, data reset ...
5−3