4. Faults and diagnostics

4.2.4 Reset types: Behaviour in the event of fault acknowledgement

Type
Description
R
Acknowledging (reset)
The reset command deletes the message. The fault is then termin
ated. It will only be reported once more if the command is repeated
without the cause of the message having been eliminated.
F
Acknowledge if cause eliminated (fix cause and reset)
The CMAX deletes the message provided the cause has been elimin
ated. If the cause has not yet been eliminated, the message is not
deleted and the fault status is not quit.
Restart (new initialisation)
N
The CMAX restarts the axis after acknowledgement. In the course of
this, the controller is re−calculated. If necessary, the components
(sensor interface and valve) are re−commissioned. All fault messages
are deleted prior to restarting.
If no fault occurs during restart, the fault status is quit after the re
start. Otherwise CCON.Fault is not reset. The maximum time for a
restart is 3 s.
Poff
Power off
Reset no longer possible, CMAX needs to be switched off.
Tab. 4/3: Acknowledging fault messages reset types
Acknowledging warnings
4−8
Depending on the type of the fault, acknowledgement leads
to various actions in the CMAX, in order to delete the active
fault message and possibly quit the fault status.
In the event of warnings, the CMAX does not have the
Fault" status, but remains Ready".
Warnings are deleted in the event of CCON.RESET or
CPOS.START (provided the cause was eliminated).
Example
E33: Target posi
tion outside of the
software or hard
ware end posi
tions
E51: Load voltage
of the controller
outside of the tol
erance range (un
dervoltage)
E60: Faulty com
munication with
the valve or no
valve present
E72: system soft
ware error
Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH