4. Faults and diagnostics

4.2.5 Error number and warning numbers

Fault group 0 configuration error
CPX error group 100 (CPX−MMI: [Configuration error] )
No.
Message
01
The nominal configur
ation deviates from
actual configuration
02
Unknown valve type
03
Unknown cylinder type
04
Unknown measuring sys
tem type or unknown
sensor interface
1)
Level: fault level, see section 4.2.3
Reset: behaviour upon reset, see section 4.2.4
Info:
= no info; x = additional info, see FCT or section 4.3.3
2)
The movement test is reset to avoid tubing errors. The CMAX has C03 status. The movement test
should then be run once more.
Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH
Cause/description
A component on the axis
string does not corres−
2)
pond to the nominal con
figuration:
Measuring system or
sensor interface
(type, length).
Cylinder (type, length,
diameter).
Valve (size).
The measuring system
and the valve were ex
changed and no longer
correspond to the nom
inal configuration or the
serial numbers have
changed.
Connected valve is not
supported.
Connected cylinder or the
sensor interface is not
supported.
Connected measuring
system or the sensor
interface is not sup
ported.
Error handling
Check component and
·
replace if necessary or
Adopt actual configur
·
ation (download).
Check configuration of
·
the axis. Check for
possible interchange
of two axis strings.
Exchange valve or
·
Update firmware.
·
Exchange cylinder or
·
sensor interface or
Update firmware.
·
Exchange measuring
·
system or sensor inter
face or
Update firmware.
·
1)
Type
Level: F2
Reset: N
Info:
Level: F2
Reset: N
Info:
Level: F2
Reset: N
Info:
Level: F2
Reset: N
Info:
4−9