Enable And Stop With Parametrisation - Festo CPX Series Manual

Description communication profile fhpp for the cmax axis controller
Hide thumbs Also See for CPX Series:
Table of Contents

Advertisement

5. Parameter

5.2.4 Enable and stop with parametrisation

5−10
The parametrisation in the cyclical I/O data requires that the
CCON.STOP signal is not set, since operation enable is not
possible.
Commissioning parameters require that the controller is
locked when writing.
Transferring parameters has the following effects on the
CCON.ENABLE and CCON.STOP signals
Operating mode
Record selection
Direct mode
Commissioning
Parametrisation
1)
With commissioning parameters CCON.ENABLE = 0 must be set
Tab. 5/6: Effect of the parameter transfer to CCON
Read: CCON
.ENABLE
.STOP
x
x
x
x
x
x
x
0
Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH
Write: CCON
.ENABLE
.STOP
x
x
x
x
0
x
1)
1)
0 / x
x / 0