5. Parameter

5.4.14 Force controller data

Force control gain factor
PNU
PNU: 1160
Values
Unit: Amplification (index = 10)
Linear drive
Dimension
SI 0,01
Imperial 0,01
The gain factor is used to increase the control amplification. It makes the controller respond to devi
ations more strongly and faster. If this factor is increased too much, the valve starts to hum. This
occurs especially with static force setpoints and with standstill control. This humming can be re
duced by varying the filter amplification or reducing the amplification.
1)
Force control is not permissible with semi−rotary drives. However, the parameter is used for stand
still control.
o The parameter value cannot be changed.
o Writing permissible only in commissioning/parametrising mode with disabled controller.
ý This parameter can be written by FCT without higher−order controller.
ý After writing, controller recalculation is carried out.
Force control dynamic gain
PNU
PNU: 1161
Values
Unit: Amplification (index = 10)
Linear drive
Dimension
SI 0,01
Imperial 0,01
Dynamic amplification is only effective in the area of the force ramp, in other words when the force
setpoint changes. This parameter is suitable for improving the truth to path in the area of the ramp,
when amplification cannot be further optimized.
1)
Force control is not permissible with semi−rotary drives. However, the parameter is used for stand
still control.
o The parameter value cannot be changed.
o Writing permissible only in commissioning/parametrising mode with disabled controller.
ý This parameter can be written by FCT without higher−order controller.
ý After writing, controller recalculation is carried out.
Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH
Index: 1
Default
Minimum
Maximum
100
10
1.000
100
10
1.000
Index: 1
Default
Minimum
Maximum
100
10
1.000
100
10
1.000
Max index: 1
Class: Var
Semi−rotary drive
Dimension Default
0,01
100
0,01
100
Max index: 1
Class: Var
Semi−rotary drive
Dimension Default
0,01
100
0,01
100
Data type: int32
1)
Minimum Maximum
10
1.000
10
1.000
Data type: int32
1)
Minimum Maximum
10
1.000
10
1.000
5−85