Configuration Of Diagnostic Messages And Faults - Festo CPX Series Manual

Description communication profile fhpp for the cmax axis controller
Hide thumbs Also See for CPX Series:
Table of Contents

Advertisement

4. Faults and diagnostics
4.4

Configuration of diagnostic messages and faults

PNU 228:01: Diagnostic events filter
Which events other than faults do you want recording?
Bit
Description
0
Record warnings
1
Record configuration events (data reset, identification etc.)
2
Record reset commands
3
Record switch−on processes
4 ... 31
reserved (=: 0 !)
Tab. 4/15: Configuration of the diagnostic messages diagnostic events filter
4−44
PNU 228 permits the configuration of diagnostic events.
PNU 228: Configuration of diagnostic events
Index
Description
1
Diagnostic events filter
2
Fault messages filter
3
Configuration of fault messages
Tab. 4/14: Configuration of the diagnostic messages
Diagnostic events filter
These settings allow you to determine which diagnostic ev
ents should be recorded. PNU 228:01 allows you to exclude
specific less important events from the diagnostic memory
records.
Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH
Default
0x0000000F
0x0000007F
0x000000C0
Specifi
cation
1
1
1
1
0