5. Parameter

5.4.7 Setpoint values for jog mode

Jog mode slow speed
PNU
PNU: 530
Values
Unit: Speed (index = 6)
Linear drive
Dimension
SI 0,001 m/s
Imperial 0.01 ft/s
Slow speed for jogging.
o The parameter value cannot be changed.
o Writing permissible only in commissioning/parametrising mode with disabled controller.
o This parameter can be written by FCT without higher−order controller.
o After writing, controller recalculation is carried out.
Jog mode fast speed
PNU
PNU: 531
Values
Unit: Speed (index = 6)
Linear drive
Dimension
SI 0,001 m/s
Imperial 0.01 ft/s
Maximum speed after expiration of the jogging slow speed period.
Depending on PNU 521:01, the corresponding default value is used instead, if necessary.
o The parameter value cannot be changed.
o Writing permissible only in commissioning/parametrising mode with disabled controller.
o This parameter can be written by FCT without higher−order controller.
o After writing, controller recalculation is carried out.
Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH
Index: 1
Default
Minimum
Maximum
50
10
500
15
3
164
Index: 1
Default
Minimum
Maximum
200
10
10.000
65
3
3.281
Max index: 1
Class: Var
Semi−rotary drive
Dimension Default
1 °/s
50
1 °/s
50
Max index: 1
Class: Var
Semi−rotary drive
Dimension Default
1 °/s
200
1 °/s
200
Data type: int32
Minimum Maximum
10
500
10
500
Data type: int32
Minimum Maximum
10
10.000
10
10.000
5−59