C. Configuration with CPX node

C.1.2 Configuration with STEP 7

Entry
CPX−CMAX−C1−1 [8 Byte I/8 Byte O]
CPX−CMAX−C1−1 [8 byte I/8 byte A Failsafe]
1)
The maximum number of parametrisation data for the CPX terminal is limited to 234.
C−4
This description refers to software version V 5.3.
An appropriate device master file (GSD file) must be installed
for configuration.
Proceed as follows for configuration (see Fig. C/1):
1. Add a DP master system 1 and the CPX terminal 2 to
the CPX−FB13, as per the description.
2. Fill the configuration table with the modules of your CPX
system.
Open the module Festo CPX terminal" (folder\PROFIBUS−
DP\Additional FIELD DEVICES\Valves\...) in the hardware
catalogue. 3 .
There are two entries for the CMAX:
Description
CMAX with 8 byte I / 8 byte O consistent,
without Failsafe parameters
(occupies 5 byte parametrising data)
CMAX with 8 byte I / 8 byte O consistent,
with Failsafe parameters
(occupies 15 byte parametrising data)
3. Assign each of the starting addresses in the Properties −
DP slave" window 4 .
This concludes the station selection and configuration.
1)
Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH