B.3 Drives And Measuring Systems - Festo CPX Series Manual

Description communication profile fhpp for the cmax axis controller
Hide thumbs Also See for CPX Series:
Table of Contents

Advertisement

B. Basic controlling principles
B.3
Drives and measuring systems
DGCI linear drive
Parameter
Measuring system type
Cylinder length
Measuring system length
Offset axis zero point
Cylinder diameter
Piston rod diameter
1)
In the CMAX drives with smaller or larger diameters will lead to errors here. A DGCI with a diameter
of e.g. 57 mm would be permissible, however.
Standard cylinders DNCI
Parameter
Measuring system type
Cylinder length
Measuring system length
Offset axis zero point
Cylinder diameter
Piston rod diameter
1)
In the CMAX cylinders with smaller or larger diameters will lead to errors here. A DNCI with a
diameter of e.g. 57 mm would be permissible, however.
B−16
The CMAX supports the following combinations of drive and
measuring system types.
Selecting a different combination is not possible in the FCT
and will lead to an error in the CMAX.
Value
Prescribed: = Digital position measuring system
Nominal length/effective length
Prescribed = cylinder length
Prescribed = 0
Selection: 18, 25, 32, 40, 50, 63, 80, 100, 125
0
Value
Prescribed: = encoder
50 mm ... 10,000 N
Prescribed: = cylinder length
Selectable within the cylinder length
Selection: 32, 40, 50, 63, 80, 100, 125
Smaller than cylinder diameter
1)
1)
Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cpx-cmax-c1-1

Table of Contents