Ccon/Scon Structure - Festo CPX Series Manual

Description communication profile fhpp for the cmax axis controller
Hide thumbs Also See for CPX Series:
Table of Contents

Advertisement

2. I/O data and sequence control

2.2.1 CCON/SCON structure

CCON
Assignment of the CCON control byte (byte 1)
B7
CCON
OPM2
Operating mode
selection
SCON
Assignment of the SCON control byte (byte 1)
SCON
B7
OPM2
Acknowledgement of
operating mode
2−8
With control byte 1 (CCON), all the states are controlled which
must be available in all operating modes.
B6
B5
OPM1
LOCK
Software
access
blockage
Control byte 1 (SCON) signals the CMAX status in all operating
modes.
B6
B5
OPM1
FCT_MMI
Device
control
software
The operating mode is defined with CCON.OPM1 and OPM2
and is acknowledged in SCON.OPM1 and OPM2.
How the control bits work together can be found under the
sequence control description in section 3.
B4
B3
RESET
Reset
fault
B4
B3
24VL
FAULT
Load
Fault
voltage
applied
Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH
B2
B1
BRAKE
STOP
Release
Stop
brake
B2
B1
WARN
OPEN
Warning
Oper
ation en
abled
B0
ENABLE
Enable
drive
B0
ENABLED
Drive en
abled

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cpx-cmax-c1-1

Table of Contents