Defining The Operating Mode With Ccon - Festo CPX Series Manual

Description communication profile fhpp for the cmax axis controller
Hide thumbs Also See for CPX Series:
Table of Contents

Advertisement

2. I/O data and sequence control

2.2.2 Defining the operating mode with CCON

Operating
CCON/SCON
mode
d
.OPM2 .OPM1
Record select
0
operating mode
(record select
mode)
Direct operating
0
mode
(direct mode)
Commissioning
1
mode
Parametrising
1
mode
Tab. 2/2: Overview of CMAX operating modes
Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH
Description
0
The PLC selects a record from a record list saved in the CMAX.
A record contains all the parameters which are specified for a
positioning task. The record number is transferred to the cyclic
I/O data as the setpoint or actual value.
1
The positioning task is transferred directly in the cyclic I/O data
(FHPP standard). The most important setpoint values (position,
speed, force) are transferred here. Supplementary parameters
(e. g. acceleration) are defined via the parametrisation.
0
Commissioning operations (e.g. identification) can be executed
and parameters can be read or written. Positioning tasks are
not possible.
1
A parameter is transferred in the I/O data according to the FPC
protocol. Positioning tasks are not possible.
Switching the operating mode
The operating mode is switched by means of the control
bytes CCON.OPM1 and CCON.OPM2 and are acknowledged in
the status bytes SCON.OPM1 and SCON.OPM2. See Tab. 2/2.
Switching the operating mode to Commissioning" or
Parametrising" is only allowed for the status Controller
disabled" (CCON.ENABLE = 0) or Controller enabled"
(CCON.STOP = 0). Switching between record select mode and
direct operating mode is additionally permitted for the status
Ready", if MC (SPOS.MC = 1).
The operating mode can also be switched if there is a Fault"
status.