Pulse output stop

The following table lists methods to stop pulse output, other than normal completion.
Select the stop method according to whether to use deceleration (deceleration stop or immediate stop) and to use the
remaining distance operation. (Page 39 Remaining distance operation)
Operation
Deceleration
Pulse output stop
Immediate stop
command
All outputs disable
Immediate stop
(SM8034)
Pulse decelerate and
Deceleration stop
stop command
Forward limit
Deceleration stop
Reverse limit
Deceleration stop
All module reset
Immediate stop
when a stop error
occurs
Turning off the
Deceleration stop
instruction drive
contact
Setting the command
Deceleration stop
speed to 0
*1 The PLSY/DPLSY instruction is stopped immediately by all the operations.
*2 Only the FX5 specified abnormal end flag is valid.
Precautions
• Note that the immediate stop may damage the machine because the motor stops immediately.
• Pulse output stop takes priority over deceleration stop. Pulse outputs are immediately stopped if an immediate stop
operation is performed during a deceleration stop operation.
5 POSITIONING INSTRUCTION
80
5.1 Common Items
*1
Abnormal end
Remaining
flag
distance
operation
ON
None
ON
None
ON/OFF
Provided
ON
None
ON
None
ON
None
*2
ON
None
ON/OFF
None
Remarks
Immediate stop without any conditions
Immediate stop without any conditions
With the corresponding instruction, the remaining
distance operation can be used.
For remaining distance operation-compatible
instructions (when the remaining distance operation
is enabled), the PLSV/DPLSV instruction (when
unlimited pulses are output), and table operation
instruction (control method: [4: Variable Speed
Operation] or [5: Table Transition Variable Speed
Operation]), the abnormal end flag does not turn on.
Effective only at forward rotation
Effective only at reverse rotation
Immediate stop if a stop processing fails during
pulse output due to a bus error
Only high-speed pulse input/output module is
supported.
Deceleration stop without any conditions
For the PLSY/DPLSY instruction, the PLSV/DPLSV
instruction and table operation instruction (control
method: [4: Variable Speed Operation] or [5: Table
Transition Variable Speed Operation]), the abnormal
end flag does not turn on.
When the command speed is changed, pulse output
is restarted.
Reference
Page 59
Page 59
Page 61
Page 61
Page 40
Page 40