Interrupt Stop (Relative Address Specification)
The following explains control method [6: Interrupt Stop (Relative Address Specification)].
Setting data
The following table shows the operand assignment.
*1
Operand 1
Description
Positioning Address
Range
-2147483648 to +2147483647
(User system unit)
Details
Set the relative address within the
range of -2147483647 to
*4
+2147483647
in pulse.
*1 The positioning address can be changed during positioning operation. (Page 36) However, only the last table accepts the change in
the case of continuous operation.
*2 Command speed can be changed during positioning operation. (Page 37)
*3 When the positioning table data is set to use device, the value can be changed during positioning operation. The change is applied when
the table operation instruction is restarted.
*4 Set the number of output pulses per table execution to 2147483647 or lower.
Processing details
Deceleration stop is performed from the point where the interrupt input signal 1 is detected during positioning operation. When
the interrupt input signal 1 is not detected, the operation becomes the same as that of the DRVI/DDRVI instruction or control
method [1: 1-speed positioning (relative address specification)]. (Page 96 Relative Positioning, Page 162 1 Speed
Positioning (Relative Address Specification))
If dwell time is set, the complete flag turns on after the dwell time elapses. (Page 77)
In addition, this table can be specified for continuous operation. (Page 193)
The following example shows an interrupt stop with dwell time 0 ms.
Speed
Drive contact of the
table operation
Interrupt input signal 1
Instruction execution
complete flag SM8029
User-specified instruction
execution complete flag
*1 Remains on until it is turned off using a program or engineering tool, restarts the table operation instruction or until the next table is
activated during the continuous operation.
*2
Operand 2
Command Speed
1 to 2147483647
(User system unit)
Set the speed within the range of
1 pps to 200 Kpps in pulse.
Acceleration
time
Command speed
(Operand 2)
*3
Operand 3
Dwell Time
0 to 32767 (ms)
Dwell time is time until the
complete flag turns on after the
positioning address is reached
(interrupt stop).
Deceleration
time
Maximum speed
Positioning address
(Operand 1)
*1
6.2 Operations of Control Method
*3
Operand 4
Interrupt Counts
1 to 32767
This is the count of inputs that are
necessary for interrupt. The
setting is enabled only in the high-
speed mode.
Bias speed
Time