Non-execution tables
Tables with positioning address setting such that no positioning is required are not executed and operation skips to the next
table during continuous operation. The following table lists table non-execution conditions.
Control method
1: 1 Speed Positioning (Relative Address Specification)
2: 1 Speed Positioning (Absolute Address Specification)
6: Interrupt Stop (Relative Address Specification)
7: Interrupt Stop (Absolute Address Specification)
*1 For example, table 2 will be non-execution if the starting address is 0 and the following settings are used.
Table No.1: The positioning address of control method [1: 1 Speed Positioning (Relative Address Specification)] is 2000.
Table No.2: The positioning address of control method [2: 1 Speed Positioning (Absolute Address Specification)] is 2000.
Precautions
The table execution ends with an error if 4 or more consecutive tables are non-execution.
Table non-execution conditions
Positioning address = 0
Positioning address = Current address when corresponding table is started
Positioning address = 0
Positioning address = Current address when corresponding table is started
*1
*1
6 TABLE OPERATION
6.3 How to Execute Multiple Tables