Complete flag and completion of positioning operation
If the complete flag of a positioning instruction is turned on, then the execution of the instruction (such as pulse outputting
operation) is complete (Page 77 Complete flag). However, it is not certain whether the servo motor has stopped or not.
Check the "positioning completion" signal of the servo amplifier (drive unit) to determine whether the servo motor has
stopped.
Write during RUN
Do not change the program if a positioning instruction is being executed (pulses are being output) in the RUN mode.
Operations will be performed as shown in the following table if a program is changed during instruction execution in RUN
mode.
Also do not change the program if PWM is being executed in RUN mode.
For details on the PWM/DPWM instructions, refer to MELSEC iQ-F FX5 Programming Manual (Instructions, Standard
Functions/Function Blocks).
Positioning instruction
Pulse Y output instruction
Mechanical OPR instruction
Relative positioning instruction
Absolute positioning instruction
Interrupt 1-speed positioning
instruction
Variable speed operation
instruction
Single-table operation
*1
instruction
Multiple-table operation
instruction
Multiple-axis table operation
instruction
*1 High-speed pulse input/output module is not supported.
Precautions
Note that immediate stop may damage the machine because the motor stops immediately.
7.3

FX3 compatible SM/SD

FX3 compatible devices can be used. Devices other than the instruction execution complete flag (SM8029) and the instruction
execution abnormal end flag (SM8329) are not supported for high-speed pulse input/output module.
Both the FX5 dedicated devices and FX3 compatible devices can be used if they have the same functionality.
For details on devices, refer to Page 47 Details of Parameters.
7 PROGRAMMING
200
7.3 FX3 compatible SM/SD
*1
PLSY/DPLSY
DSZR/DDSZR
DRVI/DDRVI
DRVA/DDRVA
DVIT/DDVIT
PLSV/DPLSV
With acceleration/
deceleration operation
Without acceleration/
deceleration operation
TBL
DRVTBL
DRVMUL
PLC operation when writing executed during
RUN while instruction is executed
Immediately stops pulse output.
Decelerates and stops pulse output.
Decelerates and stops pulse output.
Immediately stops pulse output.
Program cannot be changed in the RUN mode.
Reference
Page 82
Page 87
Page 96
Page 104
Page 113
Page 122
Page 130
Page 138
Page 147