5.5

Absolute Positioning

This instruction performs 1-speed positioning in the absolute method (positioning operation with an absolute address).
Specify the distance (absolute address) from the origin to the target position. In this case, any position can be the start point
(current position).
Address 100
0
Origin
DRVA/DDRVA
This instruction executes 1-speed positioning by absolute address.
Ladder
(s1)
Setting data
■Description, range, data type (DRVA)
• FX5 operand
Operand
Description
(s1)
Word device number storing the positioning address or
*1
data
(s2)
Word device number storing command speed or data
(d1)
Axis number from which pulses are output
(d2)
Bit device number of the instruction execution complete
flag and abnormal end flag
5 POSITIONING INSTRUCTION
104
5.5 Absolute Positioning
Address 150
Address 100
100
Point A
(s2)
(d1)
(d2)
Address 100
Address 300
Address 100
150
Point B
ST
ENO:=DRVA(EN,s1,s2,d1,d2);
ENO:=DDRVA(EN,s1,s2,d1,d2);
Range
-32768 to +32767
(User system unit)
*2
1 to 65535
(User system unit)
*3
K1 to 12
Address 150
FBD/LD
Data type
16-bit signed binary
16-bit unsigned binary
16-bit unsigned binary
Bit
Start point
End point
300
Point C
EN
ENO
s1
d2
s2
d1
Data type (label)
ANY16
ANY16
ANY_ELEMENTARY
(WORD)
ANY_BOOL

Advertisement