Hold/Clear of output at CPU STOP and at CPU stop error

1
This function sets Hold/Clear of the auto refresh device output when CPU module operation of the cyclic master is at STOP or
at CPU stop error.
The following shows the servo amplifier status at CPU STOP and at stop error.
Motion mode
When both the motion control axis and motion non-control axis are at CPU STOP, the servo amplifier stops the servo motor in
the manner commanded by the controller. At a stop error, the servo amplifier stops the servo motor by activating the dynamic
brake.
The operation may vary depending on the type of the servo system controller and firmware version.

Remote reset

Resetting can be done by sending the reset command to the specified station.
The reset command can be sent from the Remote Operation window of GX Works3.
Refer to the following for details.
Page 16 Remote Operation
1 CC-Link IE TSN
19
1.3 Application function