6
TABLE OPERATION
This chapter explains the table operation in the following items.
• How to use the positioning table in GX Works3
• Operations of each control method
• How to execute multiple tables (stepping operation and continuous operation)
6.1
How to Use the Positioning Table
The following procedure is required to perform positioning in table operation.
1.
Set the positioning parameter in the high speed I/O parameter of GX Works3. (Page 41 Setting Method)
2.
Set the table data in the high speed I/O parameter of GX Works3. (Page 158 How to Use the Positioning Table)
3.
Program the table operation instruction. (Page 196 Table Operation Instruction)
This section explains procedure 2 above.
Table setting method
Set the table in the high speed I/O of GX Works3.
Window
■CPU module
Navigation window Parameter FX5UCPU Module Parameter High Speed I/O Output Function
Positioning Detailed Setting Axis #1 Positioning Data to Axis #4 Positioning Data
■High-speed pulse input/output module
Navigation window Parameter Module Information Right-click Add New Module
After adding the high-speed pulse input/output module, make settings on the screen displayed from the following operation.
Navigation window Parameter Module Information 1 to 16 (high-speed pulse input/output module) Module
Parameter Output Function Positioning Detailed Setting Axis #5 Positioning Data to Axis #12 Positioning
Data
Shown above is the screen at the time of the selection of the data for axis 5 positioning.
6 TABLE OPERATION
158
6.1 How to Use the Positioning Table