Operations Of Control Method; No Positioning - Mitsubishi Electric MELSEC iQ-F FX5 User Manual

Programmable controller
Hide thumbs Also See for MELSEC iQ-F FX5:
Table of Contents

Advertisement

6.2

Operations of Control Method

The following explains the control method that can be set in a table.
For details of each table operation instruction, refer to Page 79 POSITIONING INSTRUCTION.

No Positioning

The following explains control method [0: No Positioning].
Setting data
The following table shows the operand assignment.
Operand 1
Description
None
Range
Details
None
Processing details
This table unconditionally turns on the positioning complete flag and ends the table operation instruction. This control method
cannot be executed before the other positioning types.
If a table that is not set with a parameter (empty table) is specified, control method [0: No Positioning] is applied.
Precautions
• If a table with this positioning type is included between the first table and last table when multiple tables are executed such
as continuous operation, tables that follow the table with control method [0: No Positioning] do not operate.
• The complete flag turns on after the operation of the previous table is decelerated to a stop and the dwell time elapses.
• When user devices are used, devices assigned to a table of control method [0: No Positioning] (first device +0 to +5) are
not used in table operation. Users can use such devices for any purpose.
Related devices
■CPU module
Axis 1
Axis 2
Axis 3
SM8029 (FX3 compatible device)
SM8329 (FX3 compatible device)
R: Read only, : Not supported
■High-speed pulse input/output module
First module
Second module
Axis 5
Axis 6
Axis 7
Axis 8
SM8029 (FX3 compatible device)
SM8329 (FX3 compatible device)
R: Read only, : Not supported
Operand 2
None
None
Axis 4
Name
Instruction execution complete flag
Instruction execution abnormal end flag
Third module
Fourth module
Axis 9
Axis 10 Axis 11 Axis 12
Operand 3
None
None
High Speed I/O
Parameter
Name
High
Speed I/O
Parameter
Instruction execution
complete flag
Instruction execution
abnormal end flag
6.2 Operations of Control Method
Operand 4
None
None
R/W
Reference
R
Page 77
R
R/W
Reference
R
Page 77
R
6 TABLE OPERATION