6.
Transfer operation will be started in the OPR direction at the OPR speed. (The workpiece will enter the near-point dog
area again.)
7.
If the front end of the near-point dog is detected, the speed will be reduced to the creep speed.
8.
After detecting the rear end of the near-point dog, if the zero signal is detected for the specified number of times is
detected, the operation will be stopped.
(4) If the limit switch in the OPR direction turns on (if the start position is at reverse
rotation limit 1):
1.
When the DSZR/DDSZR instruction is executed, OPR will be started.
2.
Transfer operation will be started in the opposite direction of the OPR direction at the OPR speed.
3.
If the front end of the near-point dog is detected, the speed will decelerate and the operation will stop. (The workpiece
will detect (come out) the near-point dog area).
4.
Transfer operation will be started in the OPR direction at the OPR speed. (The workpiece will enter the near-point dog
area again.)
5.
If the front end of the near-point dog is detected, the speed will be reduced to the creep speed.
6.
After detecting the rear end of the near-point dog, if the zero signal is detected for the specified number of times is
detected, the operation will be stopped.
When the same device is specified for the near-point dog signal and the zero signal and OPR zero signal
counts is 1, OPR is stopped when the OPR is completed by the near-point dog signal detection, not by the
zero signal detection. When the timing of counting start of the number of zero signals is set to the front end of
near-point dog, the number of zero signals is counted from when the near-point dog signal is detected.

Dwell time

Set the time (dwell time) until the complete flag turns on after positioning operation is completed between 0 to 32767 ms.
When the positioning operation is completed, the complete flag remains off until the dwell time has elapsed.
Dwell time applies to the DSZR/DDSZR instruction and the table operation instruction. If the CLEAR signal is output by the
DSZR/DDSZR instruction, the dwell time applies when the CLEAR signal turns off.
Set the dwell time of DSZR/DDSZR instruction with the positioning parameter. (Page 67 OPR Dwell Time) Set the dwell
time of the table operation instruction for the control method of each table with the table operation parameter. (Page 70
Dwell Time)
OPR (DSZR/DDSZR) instruction
Zero signal
Complete flag
(With dwell time)
Complete flag
(Without dwell time)
3 POSITIONING CONTROL FUNCTION
34
3.4 Auxiliary Function
Deceleration
time
Creep speed
Origin
Near-point
DOG
Dwell time
Table operation instruction
(control method: [1 Speed Positioning])
Command
OPR
speed
speed
Complete flag
(With dwell time)
Complete flag
(Without dwell time)
Deceleration
time
Positioning address
Dwell time