■Description, range, data type (DDRVI)
• FX5 operand
Operand
Description
(s1)
Word device number storing the positioning address or
*1
data
(s2)
Word device number storing command speed or data
(d1)
Axis number from which pulses are output
(d2)
Bit device number of the instruction execution complete
flag and abnormal end flag
• FX3 compatible operand (Supported only for CPU module)
Operand
Description
(s1)
Word device number storing the positioning address or
*1
data
(s2)
Word device number storing command speed or data
(d1)
Output bit device number (Y) from which pulses are output
(d2)
Bit device number from which rotation direction is output
*1 The positioning address can be changed during positioning operation.
*2 Command speed can be changed during positioning operation.
*3 CPU module: K1 to 4 (Axis 1 to Axis 4)
High-speed pulse input/output module: K5 to 12 (Axis 5 to Axis 12)
■Available device (DRVI/DDRVI)
• FX5 operand
Operand
Bit
X, Y, M, L, SM,
F, B, SB, S
(s1)
(s2)
(d1)
*2
(d2)
• FX3 compatible operand (Supported only for CPU module)
Operand
Bit
X, Y, M, L, SM,
F, B, SB, S
(s1)
(s2)
*4
(d1)
*5
(d2)
*1 Only available for DDRVI instruction.
*2 Two devices are occupied from the specified device.
*3 T, ST, C cannot be used.
*4 Only Y0 to Y3 devices can be used.
*5 When the output mode is CW/CCW, specify the CCW axis. When the output mode is PULSE/SIGN, only the SIGN output of the axis or
general-purpose output can be specified.
Processing details
This instruction executes 1-speed positioning by relative address. The target positioning address is specified in the
incremental method, in which transfer direction and transfer distance (relative address) from current address are specified for
positioning operation.
*2
*2
Word
T, ST, C, D, W,
U\G
SD, SW, R
*3
Word
T, ST, C, D, W,
U\G
SD, SW, R
*3
Range
Data type
-2147483648 to +2147483647
32-bit signed binary
(User system unit)
1 to 2147483647
32-bit signed binary
(User system unit)
*3
K1 to 12
16-bit unsigned binary
Bit
Range
Data type
-2147483648 to +2147483647
32-bit signed binary
(User system unit)
1 to 2147483647
32-bit signed binary
(User system unit)
0 to 3
Bit
Bit
Double word Indirect
specification
Z
LC
LZ
*1
*1
*1
*1
Double word Indirect
specification
Z
LC
LZ
*1
*1
*1
*1
Data type (label)
ANY32
ANY32
ANY_ELEMENTARY
(WORD)
ANY_BOOL
Data type (label)
ANY32
ANY32
ANY_ELEMENTARY
(BOOL)
ANY_BOOL
Constant
Others
K, H
E
$
Constant
Others
K, H
E
$
5 POSITIONING INSTRUCTION
5.4 Relative Positioning
5
97