Precautions
Other than the following, the same as cautions for the DVIT/DDVIT instruction apply.
• Combinations other than the following cannot be used during continuous operation.
The first table
Control method
3: Interrupt 1 Speed Positioning
5: Table Transition Variable Speed Operation
Control method [3: Interrupt 1 Speed Positioning] must be specified to the first or second table. If control method [3: Interrupt
1 Speed Positioning] is specified to the second table, only control method [5: Table Transition Variable Speed Operation] can
be specified to the first table.
• Continuous operation can not be used for the high-speed pulse input/output module. If this table is specified for continuous
operation for the high-speed pulse input/output module, an error occurs.
Related devices
Other than the following, the related devices are the same as those of the DVIT/DDVIT instruction.
■Special relays
• CPU module
Axis 1
Axis 2
Axis 3
SM5916
SM5917
SM5918
R/W: Read/write, : Not supported
• High-speed pulse input/output module
First module
Second module
Axis 5
Axis 6
Axis 7
Axis 8
SM5920
SM5921
SM5922
SM5923
R/W: Read/write, : Not supported
■Special registers
• CPU module
Axis 1
Axis 2
Axis 3
SD5506
SD5546
SD5586
SD5511
SD5551
SD5591
R: Read only, R/W: Read/write, : Not supported
• High-speed pulse input/output module
First module
Second module
Axis 5
Axis 6
Axis 7
Axis 8
SD5666
SD5706
SD5746
SD5786
SD5671
SD5711
SD5751
SD5791
R: Read only, R/W: Read/write, : Not supported
Axis 4
Name
SM5919
Positioning table data initialization disable
Third module
Fourth module
Axis 9
Axis 10 Axis 11 Axis 12
SM5924
SM5925
SM5926
Axis 4
Name
SD5626
Positioning execution table number
SD5631
Positioning error (error occurrence table No.)
Third module
Fourth module
Axis 9
Axis 10 Axis 11 Axis 12
SD5826
SD5866
SD5906
SD5831
SD5871
SD5911
The second table
3: Interrupt 1 Speed Positioning
High Speed I/O
Parameter
Name
SM5927
Positioning table data
initialization disable
High Speed I/O
Parameter
Name
SD5946
Positioning execution table
number
SD5951
Positioning error (error
occurrence table No.)
6.2 Operations of Control Method
R/W
Reference
R/W
Page 74
High
R/W
Reference
Speed I/O
Parameter
R/W
Page 74
R/W
Reference
R
Page 73
R/W
Page 74
High
R/W
Reference
Speed I/O
Parameter
R
Page 73
R/W
Page 74
6 TABLE OPERATION