REP 10.1 Duplex Motor

Parts List on PL 10.20
Removal
WARNING
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
WARNING
Take care during this procedure. Sharp edges may be present that can cause injury.
CAUTION
Before performing this procedure, refer to General Disassembly Precautions, GP 10.
1.
Remove the right cover, REP 28.1.
2.
Remove the duplex drive assembly, PL 10.20 Item 13.
3.
Remove the duplex motor, PL 10.20 Item 1 from the drive assembly.
Replacement
1.
Replacement is the reverse of the removal procedure.
Draft 4
Phaser 3635MFP

REP 10.2 Exit Motor

Parts List on PL 10.20
Removal
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
Take care during this procedure. Sharp edges may be present that can cause injury.
Before performing this procedure, refer to General Disassembly Precautions, GP 10.
1.
Remove the right cover, REP 28.1.
2.
Disconnect the harness from the exit motor, PL 10.20 Item 4.
3.
Remove the exit drive assembly, Figure 1.
Figure 1 Exit drive assembly removal
4.
Remove 4 gears from the exit drive assembly to gain access to the motor mounting
screws, refer to PL 10.20.
5.
Remove 2 screws to remove the exit motor from the exit motor bracket.
Replacement
1.
Replacement is the reverse of the removal procedure.