Displaying A Hardware Status Code; Table 6-4 Hardware Status Code And Cause/Action - Hitachi HF-BX1000 Instruction Manual

Industrial computer
Table of Contents

Advertisement

6.6.2 Displaying a hardware status code

A hardware status code is displayed when an error occurs in the hardware during system
operation.
When the hardware status code is displayed, the RAS status lamp (red) in the status
indication LEDs is lit.
Status code
11
12
21
31
32
41
42
4B
4C
4D
(*)
(*) This code is not displayed in default setting. Read the description of HF-BX1000/1200 RAS
FEATURES MANUAL "5.3 RAID Configuration Control Command (raidctrl) (D Model
Only)" when you want to display this code.
< NOTE >
• If a code other than one of the above is displayed, contact the system
administrator or maintenance personnel.

Table 6-4 Hardware Status Code and Cause/Action

Cause
Rotation of the case fan is abnormal.
Rotation of the CPU fan is abnormal.
The temperature is abnormal.
Failure is predicted for the drive in
drive bay 1.
Failure is predicted for the drive in
drive bay 2.
The drive bay1 is abnormal.
The drive bay2 is abnormal.
RAID array is failure (HDD failure in
both sides.)
RAID status is unknown (RAS
software could not get the RAID
status.)
Media error is occurred on RAID.
Read the description in subsection
6.2.2 (1) and take action
accordingly.
Read the description in subsection
6.2.2 (1) and take action
accordingly.
We recommend you back up the
data and replace the drive.
Read the description of "8.4.2" and
replace an HDD.
Contact your system administrator
or maintenance personnel.
Contact your system administrator
or maintenance personnel.
Read the description in subsection
8.4.2 and take action accordingly.
6-25
6. TROUBLESHOOTING
Action

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hf-bx1200