7.3.4 Countermeasures when changing the memory dump collection setting

Follow the flow chart below to take appropriate actions.
<Flow>
Start
Do you want to change
the recommended for
the equipment?
Click Yes and close the
message box.
Change the memory dump
setting to the one recommended
for the equipment.
Restart the system.
Reserve the area for saving a
memory dump.
Were you able to reserve
No
the area for saving a
memory dump?
End
No
Yes
Click No and close the
message box.
End
Yes
<Description of the action>
For details, see "7.3.5 (2) Specifying a memory dump file".
Use the "createdmp" command.
For details, see "7.5 Maintenance Operation Commands".
7-10
This message box will not be
displayed after this.