Displaying A Hardware Status Code; Table 9-6 Hardware Status Code And Cause/Action - Hitachi HF-W2000 Instruction Manual

Industrial computer
Table of Contents

Advertisement

9.6.2 Displaying a hardware status code

A hardware status code is displayed when an error occurs in the hardware during system
operation.
When the hardware status code is displayed, the RAS status lamp (red) in the status
indication LEDs is lit.
Status code
11
Rotation of the power supply fan is abnormal.
12
Rotation of the system fan is abnormal.
13
Rotation of the CPU fan is abnormal.
21
The temperature is abnormal.
31
Failure is predicted for the drive in drive bay 1.
32
Failure is predicted for the drive in drive bay 2.
41
The drive bay1 is abnormal.
(*1)
42
The drive bay2 is abnormal.
(*1)
RAID status is unknown (RAS software could
4C
not get the RAID status.)
4D
Media error is occurred on RAID.
(*2)
(*1) This code is also displayed during rebuilding.
(*2) This code is not displayed in default setting. Read the description of RAS FEATURES MANUAL
"2.8.2" when you want to display this code.
< NOTE >
If a code other than one of the above is displayed, contact the system administrator
or maintenance personnel.

Table 9-6 Hardware Status Code and Cause/Action

Cause
Read the description in "9.2.2 (1)"
and take action accordingly.
Read the description in "9.2.2 (1)"
and take action accordingly.
We recommend you back up the
data and replace the drive.
Read the description of "10.4.2"
and replace an HDD.
Contact your system administrator
or maintenance personnel.
Read the description of RAS
FEATURES MANUAL "2.8.2"
and take action accordingly.
9-33
9. TROUBLESHOOTING
Action