ALARM-PT (ALARM PORT)

Table 29: ALARM-PT (ALARM PORT)
MO Name (in Alarm
Log)
ALARM-PT
ALARM-PT
Note: You must consult local records for the location and designation of the equipment rack
where the G350 is mounted.
The Alarm Port MO provides on-board maintenance for an analog line port that is administered as an
external device alarm port. Test are provided to verify the analog line port's ability to detect an external
device alarm. The external device alarm (EXT-DEV) MO is used for the off-board external device alarm.

Error Log entries and Test to Clear values

Table 30: 8-Port Analog Line Error Log Entries
Error
Aux
Type
Data
0*
0
15 (a)
Any
18
0
130 (b)
769
*Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Notes :
(a) This is a software audit error that does not indicate any hardware malfunction. Run Short Test
SeSquence and investigate errors.
(b) Indicates that the Media Module has been removed or has been insane for more than
11 minutes. To clear the error, reseat or replace the Media Module.
Maintenance of the Avaya G350 Media Gateway
June 2004
Avaya Communication Manager controlled maintenance
Alarm
Level
Initial Command to Run
MIN
test port GGGVSPP l
WRN
test port GGGVSPP sh
Associated
Alarm
Test
Level
Any
Any
Audits and
Updates Test
(#36)
busy-out station
WARNIN
extension
G
None
WARNIN
G
Battery Feed Test
MINOR
(#35)
ALARM-PT (ALARM PORT)
Full Name of MO
Alarm-Port
Alarm-Port
On/Off
Board
Test to Clear Value
Any
test port GGGVSpp sh r 1
OFF
release station extension
ON
test port GGGVSpp sh
ON
test port GGGVSpp sh r 2
73