Technician-Demand Tests: Descriptions And Error Codes; Port Audit And Update Test (#36) - Avaya G350 Maintenance Manual

Hide thumbs Also See for G350:
Table of Contents

Advertisement

Technician-Demand Tests: Descriptions and
Error Codes
Always investigate tests in the order presented in the table below when inspecting errors in the system.
By clearing error codes associated with the NPE Crosstalk Test, for example, you may also clear errors
generated from other tests in the testing sequence.
Table 128: Technician-Demand Tests
Order of Investigation
NPE Crosstalk Test (#6)
Note: This Test ABORTS with code 1412
when run on a Avaya G350 Media Gateway
system.
Conference Circuit Test (#7)
Note: This Test ABORTS with code 1412
when run on a Avaya G350 Media Gateway
system.

Port Audit and Update Test (#36)

*D = Destructive; ND = Nondestructive
Port Audit and Update Test (#36)
This test sends port level translation data from switch processor to the MG-DS1 Interface Media Module
to ensure that the wideband access endpoint port's translation is correct.
Table 129: TEST #36 Audit and Update Test 1 of 2
Error
Test
Code
Result
ABORT
1006
ABORT
2000
ABORT
Maintenance of the Avaya G350 Media Gateway
June 2004
Avaya Communication Manager controlled maintenance
Description/ Recommendation
Internal system error
Retry the command at 1-minute intervals a maximum of 5 times.
The port is out-of-service. If the port is busied out:
Use release access-endpoint <extension> command to put the port
back into in-service.
Retry the test command. If the port is not busied out:
Check the error and alarm logs for WAE-PORT and MM-DS1 errors and
alarms and follow the recommended repair procedures.
Response to the test request was not received within the allowable time
period.
Retry the command at 1-minute intervals a maximum of 5 times.
WAE-PORT (Wideband Access Endpoint Port)
Short Test
Long Test
Sequence
Sequence
X
X
X
X
D/ND*
ND
ND
ND
1 of 2