Status Of Parameter Downloads - Avaya G350 Maintenance Manual

Hide thumbs Also See for G350:
Table of Contents

Advertisement

Feature Access Code
A Refresh Terminal Parameters Feature Access Code can be used to request a terminal download action.
When this code is followed by a "#", the programmable parameters for the current terminal are
downloaded when the terminal goes on hook. When this code is followed by an extension, the
programmable parameters for the specified station are downloaded.
This Refresh Terminal Parameters Feature Access Code is assigned on the second page of the "feature-
access-codes" screen.
A confirmation is returned if the download request is accepted. A busy tone is returned if the request is
made from a different station when the target station is off-hook.
The first three green call appearance LEDs on the 84xx 603x terminal will be turned on for three seconds
if the station was successfully downloaded as a result of an entry of a Refresh Terminal Parameters
Facility Access Code. This is not true for the 302B1 terminal.
There is no visible display on a station for the other background or demand download actions. As
described below, the "status station" and "status attendant" screens can be used to check the download
status of a specified terminal.

Status of Parameter Downloads

The "status station" and "status attendant" screens display the current download status of individual
84xx terminals in the Download Status field. The possible download states are:
Table 63: Download States
Status
Complete
Pending
Not Applicable
Possible reasons for terminal being not downloaded include:
Terminal is off-hook.
Terminal detected a bad checksum.
Terminal detected a bad or missing EEPROM (refer to hardware error log).
Terminal is busy programming data from a previous PROGRAM message.
Terminal is in the Programming Disabled state.
Terminal is in the Local Program Options Mode.
Terminal is disconnected or out of service (use status station command).
Maintenance of the Avaya G350 Media Gateway
June 2004
Avaya Communication Manager controlled maintenance
Explanation
Terminal successfully downloaded sometime in the past.
System waiting to download the terminal. This may require the execution of
a background periodic test which could take more than an hour. A demand
download as described above may also be used to initiate an immediate
download.
Not a programmable terminal.
DIG-LINE (Digital Line)