Mo Test Commands; Abort Code 1412 - Avaya G350 Maintenance Manual

Hide thumbs Also See for G350:
Table of Contents

Advertisement

Avaya Communication Manager controlled maintenance

MO test commands

MO test commands
Each command is arranged according to a standard command syntax for Avaya G350 Media Gateways,
where GGG is the G350 Number, the character V indicates that this system is a G350, S is the slot
number, and PP is the port number.
Full test commands can be either short or long as indicated, and can be repeated several times. For
example, in:
test port GGGVSpp sh r 1
sh = short
r = repeat
1 = the number of times the test should be repeated.
Similarly, in:
test port GGGVSpp l r 2
l = long
r = repeat
2 = the number of times the test should be repeated.

Abort Code 1412

Tests that do not run on the G350 will abort with Abort Code 1412. Tests that abort are listed under each
MO, but are not described.
72
Maintenance of the Avaya G350 Media Gateway
June 2004

Advertisement

Table of Contents
loading

Table of Contents