Dig-Line (Digital Line) - Avaya G350 Maintenance Manual

Hide thumbs Also See for G350:
Table of Contents

Advertisement

Table 60: TEST #36 Port Audit Update Test 2 of 2
Error
Test
Code
Result
FAIL
PASS
Any
NO
BOARD

DIG-LINE (Digital Line)

Table 61: DIG-LINE (Digital Line)
MO Name (in
Alarm Log)
DIG-LINE
DIG-LINE
Note: You must consult local records for the location and designation of the equipment rack
where the G350 is mounted.
DIG-LINE maintenance monitors and tests ports on digital line Media Modules and the hardware
connected to those ports for lines administered as a digital station. These include stations with just a
digital voice terminal and stations with a digital voice terminal and a linked data module. Media
Gateway-level maintenance is covered by "MG-DCP" whose strategy is described in the "XXX-BD
(Common Port Media Module)" section.
Digital line maintenance interacts with digital line Media Module (MG-DCP) maintenance, and results of
DIG-LINE testing can be affected by the health of the digital line Media Module. Keep this in mind when
investigating digital line problems. There are instances where the service state of a station is mentioned.
Maintenance of the Avaya G350 Media Gateway
June 2004
Avaya Communication Manager controlled maintenance
Description/ Recommendation
Internal system error
Retry the command at 1-minute intervals a maximum of 5 times.
This test passed. Translation information was successfully updated on the
Media Module.
If signaling troubles are reported (Error Types 1, 257, or 513), verify
translation for this port.
Refer problem to the CO.
The test could not relate the internal ID to the port.
Check to ensure that the board translations are correct. Translate the
board, if necessary.
Use the busyout board command.
Use the reset board command.
Use the release busy board command.
Use the test board command. This should re-establish the linkage
between the internal ID and the port.
If the problem persists, replace the circuit pack.
Alarm Level
Initial Command to Run*
MINOR
test port GGGVSpp l
WARNING
test port GGGVSpp sh
DIG-LINE (Digital Line)
2 of 2
Full Name of MO
Digital Line
Digital Line
117

Advertisement

Table of Contents
loading

Table of Contents