System Technician-Demanded Tests:
Descriptions and Error Codes
CAUTION:
Always investigate tests in the order they are presented in the table below when inspecting
errors in the system. By clearing error codes associated with the NPE Crosstalk Test, for
example, you may also clear errors generated from other tests in the testing sequence.
Table 99: Order of Investigation
Order of Investigation
NPE Audit Test (#50)
Note: This test will abort with Error
Code 1412.
Ringing Application Test (#51)
Aborts with code 1412
Control Channel Looparound Test (#52)
SAKI Sanity Test (#53)
NEON Test (#220)
Aborts with code 1412
D = Destructive; ND = Nondestructive
*
For hardware error log entries and for more information on the tests listed in the table above refer to "MO
XXX-BD (common port Media Module)" maintenance object documentation.

MG-BRI (BRI Trunk Media Module MM720 and MM722)

Table 100: MG-BRI (BRI Trunk Media Module MM720 and MM722)
MO Name
(in Alarm Log)
MG-BRI
* Where GGG is the administered Media Gateway number, VM is the Media Module slot number (V1, if no
S8300, through V4), and, if required in a port command, pp is a two-digit port number (01 - 08).
The MM720 and MM722 BRI Media Modules contain eight, 4-wire ports that interface to the network at
the ISDN S/T reference point over two 64 Kb/s channels (B1 and B2) and over a 16Kb/s signaling (D)
channel.
Maintenance of the Avaya G350 Media Gateway
June 2004
Avaya Communication Manager controlled maintenance
MG-BRI (BRI Trunk Media Module MM720 and MM722)
Short Test
Sequence
X
Alarm Level
Initial Command to Run
MINOR
test board GGGVM*
Long Test
Reset Board
Sequence
Sequence
X
X
X
D
*
Full Name of MO
MO_MG_BRI
D/ND
*
ND
ND
169