Mg-Dcp (Digital Line Media Module) - Avaya G350 Maintenance Manual

Hide thumbs Also See for G350:
Table of Contents

Advertisement

Avaya Communication Manager controlled maintenance

MG-DCP (Digital Line Media Module)

Control Channel Loop Around Test (#52)
Refer to the repair procedure described in the "XXX-BD (Common Port Circuit Pack)" section.
NPE /NCE Audit Test (#50)
This test will abort with ABORT CODE 1412. This test is an audit that sends network update messages to
various ports on a board. Since the Media Server does not handle network connections for the Media
Gateway, this test is not intended to be run.
SAKI Sanity Test (#53)
CAUTION:
This test is destructive.
Refer to the repair procedure described in the "XXX-BD (Common Port Circuit Pack)" section. This test
is only run as a part of a reset board procedure.
LAN Receive Parity Error Counter Test (#595)
The test reads and clears a circuit pack's LAN Receive Parity Error Counter.
MG-DCP (Digital Line Media Module)
DIG-LINE maintenance monitors and tests ports on digital line Media Modules and the hardware
connected to those ports for lines administered as a digital station. Media Gateway-level maintenance is
covered by "MG-DCP" whose strategy is described in the "XXX-BD (Common Port Media Module)"
section.
Table 103: MG-DCP (MM712 and MM312 Digital Line Media Module)
MO Name (in
Alarm Log)
MG-DCP
MG-DCP
Note: You must consult local records for the location and designation of the equipment rack
where the G350 is mounted.
NOTE:
Refer to XXX-BD (Common Port Media Module) for Media Module level errors. See also
"DIG-LINE" for related line information.
174
Alarm Level
Initial Command to Run*
MIN
test board GGGVS sh
WRN
test board GGGVS sh
Maintenance of the Avaya G350 Media Gateway
Full Name of MO
Digital Line Media
Module
Digital Line Media
Module
June 2004